DT System Technical Guide 8
DIP Switches settings
Total 6 bits in the DIP switches can be congured. The switches can be modied either before or after installation.
• Bit1 and Bit 2 is for Door Station ID settings, when mutil Door Stations are installed in the system, these two bit
must be set correctly, the rst Door Station set to 00, the second one set to 01, the third one set to 10, the fourth
one set to 11. If only one Door Station is installed, set to 00.
• Bit3: Single line button Door Station or double line button Door Station selection. If the Door Station is a double
line button, for examlpe, the DMR11D8, set this bit to 0, set to 1 for single line button Door Stations.
• Bit4: Button code selection; if use the default codes for each button of the Door Station, set to 0, if use the
programmed codes, set to 1.(the code for each button can be programmed by the DT CONFIG software, see the
program section in this manual)
• Bit5: Unlocking time quick selection, by default it is set to 0, for 1 second unlocking time; set to 1 for 5 seconds.
(this 5 second unlocking time can be changed by DTCONFIG software)
• Bit6: MUST be set to off.
ON(1)
=
OFF(0)
=
ON
ON
ON
1 2 3 4 5 6
Bit denition Bit state Function Descriptions
Bit1 and bit2
Door Station ID setting
1 2 3 4 5 6
ON
Default setting, ID = 0, set to the rst Door Station.
1 2 3 4 5 6
ON
ID = 1, set to the second Door Station.
1 2 3 4 5 6
ON
ID = 2, set to the third Door Station.
1 2 3 4 5 6
ON
ID = 3, set to the fourth Door Station.
Bit3
User ID select
1 2 3 4 5 6
ON
Default setting for using a double line button Door Station.
1 2 3 4 5 6
ON
when using a single line button Door Station.
Bit4
Button line select
1 2 3 4 5 6
ON
Default setting for using the default codes of the button.
1 2 3 4 5 6
ON
using the progremmed codes of the button.
Bit5
Unlocking time quick select
1 2 3 4 5 6
ON
Default setting, unlocking time = 1 second.
1 2 3 4 5 6
ON
Unlocking time = 5 seconds.(can be changed by software)
Bit6
Function reserved
1 2 3 4 5 6
ON
Working state.
1 2 3 4 5 6
ON
Function reserved.
Commentaires sur ces manuels